A three-way thermostatic control valve regulates the diesel engine cooling water temperature by passing a portion of the water ().
A . around the engine
B . around the cooler
C . to the expansion tank
D . overboard
相似题目
-
Thermostatic expansion valves can be adjusted for ().
A . suction pressure only
B . head pressure only
C . superheat only
D . suction pressure and box temperature
-
A ruptured diaphragm in a thermostatic expansion valve will cause the valve to ().
A . open
B . close
C . remain in its position
D . flood the evaporator with refrigerant
-
If the operating element of a thermostatic valve installed in a diesel engine cooling system malfunctions, it may result in ()
A . a low level in the engine expansion tank
B . excessively high coolant pressure
C . improper temperatures
D . malfunctioning of the jacket water heater
-
Fire alarm system thermostats are actuated by().
A . smoke sensors
B . the difference in thermal expansion of two dissimilar metals
C . pressure loss due to air being heated
D . an electric eye which actuates when smoke interferes with the beam
-
floata,b,c,问等式(a+b)+c==(b+a)+c和(a+b)+c==(a+c)+b能否成立?
-
In order to maintain a constant outlet water temperature of 80-85℃ from the engine, a three-way valve is installed()
A . at the jacket cooler outlet to control the flux through the engine
B . at the jacket cooler outlet to control the flux through the cooler
C . at the engine outlet to control the flux through the engine
D . at the engine inlet to control the flux through the engine
-
A thermostatic expansion valve is properly controlling evaporator superheatAdjusting this valve to lower the superheat will result in a/an ().
A . evaporator pressure decrease
B . evaporator coil over-feed
C . evaporator capacity increase
D . expansion valve diaphragm rupture
-
Thermostatic steam pressure reducing valves are used in the fuel oil service system to control the()
A . double bottom fuel oil tank temperature
B . heater supply steam flow
C . pressure of the fuel supplied to the burners
D . attemperator steam flow in the heater discharge circuit
-
If an auxiliary diesel engine temperature is higher than normal ,but the thermostat is determined not to be defective you would suspect a /an ()
A . cavitation erosion in the water jackets
B . excess corrosion inhibitor in the coolant
C . dirty jacket water cooler
D . defective turbocharger
-
A cracked diaphragm in a thermostatic expansion valve will cause the valve to ().
A . return to a neutral position
B . flood the evaporator
C . open
D . close
-
Which of the listed statements is a characteristic of the liquid charged power element used with thermostatic expansion valves?()
A . At the designed operating temperature, the liquid refrigerant charge has changed to a vapor
B . The liquid refrigerant tends to collect at the bellows or diaphragm and reduces the valve sensitivity
C . The sensing bulb is empty of liquid refrigerant charge at the designed operating temperature
D . The sensing bulb is never emptied of liquid refrigerant under normal operating conditio
-
int a=1,b=2,c=3;if(a>c)b=a;a=c;c=b;则c的值为2.
-
当a=1,b=2,c=3时,执行以下程序段后a=【1】.if(a>c)b=a;a=c;c=b;
-
当a,b,c的值分别为3,4,5时,以下各语句执行后a,b,c的值为多少( )if (a>c){a=b; b=c; c=a;}else{a=c; c=b; b=a;}printf(“%d,%d,%d”,a,b,c);
-
设(A,*)为群,任意a,b,c∈A,如果a*b=a*c,则b=c。
-
如下程序的输出结果是 。 main( ) { int a=1,b=2,c=3; if(a>c) b=a; a=c; //a=3 c=b; //c=2 printf(\a=%d,b=%d,c=%d\\n\,a,b,c); }
-
设有定义:int a=1,b=2,c=3;以下语句中执行效果与其他三个不同的是A) if(a>b) {c=b,a=b,b=c;}B) if(a>b) {c=a,a=b,b=c;}C) if(a>b) c=a;a=b;b=c;D) if(a>b) {c=a;a=b;b=a;}
-
a、b、c三个数,已知a×b=24,a×c=36,b×c=54,求a+b+c=()。
A.23
B.21
C.19
D.17
-
表示关系a≤b≤c的C语言表达式为()。A.(a<=B) &&(b<=C)B.(a<=B) and(b<=C)C.(a<=b<=C)D.(a<
表示关系a≤b≤c的C语言表达式为()。
A.(a<=B) &&(b<=C)
B.(a<=B) and(b<=C)
C.(a<=b<=C)
D.(a<=B) &(b<=C)
-
当a=1,b=2,c=3时,执行以下程序段后a=【1】.if (a>c) b=a;a=c;c=b;
-
设为一个半群,a,b,c为S中的给定元素.证明:若a,b,c满足a*c=c*a,b*c=c*b那么(a*b)*c=c*(c*b).
设<img src='https://img2.soutiyun.com/ask/2021-01-04/978612143224146.png' />为一个半群,a,b,c为S中的给定元素.证明:若a,b,c满足
a*c=c*a,b*c=c*b
那么(a*b)*c=c*(c*b).
-
When we stay at a room in a house with central air-conditioning system in summer, we should set the thermostat to a higher level in ______.
-
【单选题】5、设[{a , b , c},*]为代数系统,*运算如下: * a b c a a b c b b a c c c c c 则零元为()。
A.a
B.b
C.c
D.没有
-
当a,b,c的值分别为3,4,5时,以下各语句执行后a,b,c的值为多少?if(a>c){a=b;b=c;c=a;}else {a=c;c=b;b=a;}()
A.5 ,5 ,4
B.3,4,5
C.4,4,5
D.5, 4,3